鐵甲工程機械網> 工程機械資訊> 行業 > GENMA維保·液壓系統 | 蓄能器:帶壓部件,安全第一

GENMA維保·液壓系統 | 蓄能器:帶壓部件,安全第一

蓄能器看起來只是個不起眼的小鋼罐,但內部充滿高壓氮氣和液壓油。操作不當可能造成嚴重傷害。

蓄能器的作用

? 應急動力:主泵失效時,提供臨時壓力(如放下臂架)

? 吸收脈動:減少液壓沖擊

? 輔助動作:補充瞬間流量

日常檢查要點

檢查壓力:停機泄壓后,在測壓口安裝壓力表。實際壓力不應低于理論壓力的20%。低于此值,需要更換。

檢查放油閥:確認球閥位置正確,無泄漏。

檢查外觀:有無磕碰、銹蝕、焊縫裂紋?有則立即停用。

維護周期

? 每10年由專業機構檢查蓄能器強度。

? 壓力不足時更換,不要自行充氣——涉及高壓氮氣,操作不當有爆炸風險。

安全警告

? 嚴禁焊接、鉆孔、切割:內部高壓氣體,遇熱可能爆炸。

? 維修前必須泄壓:先關閉球閥,慢慢擰松節流閥,確認壓力表讀數為0后再操作。

? 不要私自拆卸:內部結構復雜,必須由專業工程師處理。

蓄能器平時默默工作,關鍵時刻提供保障。記住兩條:帶壓必泄壓,測壓不足就換。

不確定如何檢查?請聯系GENMA售服工程師。安全第一,別自己硬來。

GENMA Maintenance · Hydraulic System | Accumulator: Pressurized Component, Handle with Care

The accumulator may look like a small steel bottle, but it's filled with high-pressure nitrogen and hydraulic oil. Mishandling can lead to serious injury.

What it does

? Emergency backup — provides temporary pressure if the main pump fails (e.g., lowering the boom)

? Dampens pulsations — reduces hydraulic shocks

? Assists fast actions — supplements flow during peak demand

Daily checks

1. Pressure — After shutting down and relieving pressure, attach a gauge to the test port. Actual pressure should not drop below 20% of the theoretical value. If lower, replace the accumulator.

2. Drain valve — Make sure the ball valve is in the correct position with no leaks.

3. Visual inspection — Check for dents, rust, or weld cracks. If any, stop using it immediately.

Service intervals

? Every 10 years, have a certified professional inspect the accumulator’s integrity.

? If pressure is too low, replace it. Never attempt to recharge it yourself — high-pressure nitrogen poses an explosion risk if mishandled.

Safety warnings

? No welding, drilling, or cutting — internal high-pressure gas can cause an explosion when heated.

? Always depressurize before maintenance — close the ball valve, slowly loosen the throttle valve, and verify the pressure gauge reads zero before proceeding.

? Never disassemble on your own — internal components are complex; always call a trained service engineer.

The accumulator works silently, ready to step in when needed. Two simple rules: depressurize before touching, and replace if pressure drops too low.

Not sure how to check it? Contact your GENMA service engineer. Safety comes first — don't take chances.