對于配備柴油發電機組的GENMA設備,發電機組是重要的動力來源。當發電機組出現異常時,觸摸屏上會顯示報警信息。及時讀懂報警、正確處理,能避免小問題演變成大故障。
柴油發電機狀態頁面可以從信息頁面訪問。觸摸屏上會顯示當前發電機組的運行狀態和報警信息。如果狀態頁面顯示報警錯誤,請及時檢查處理。
常見檢查方向:
1、油液液位與滲漏
檢查潤滑油位和冷卻液位
檢查燃油、潤滑油、冷卻液是否有滲漏
2、運行參數
檢查機油壓力和冷卻水溫度
檢查動力性有無變化
檢查發動機聲音有無異響
檢查煙色有無異常
3、進氣與燃油系統
每50小時檢查進氣阻力指示器,或更換空濾芯
每50小時放掉燃油箱中的水和沉積物
每50小時放掉油濾中的水和沉積物
4、皮帶與風扇
檢查皮帶松弛和磨損
檢查風扇有無損壞
如果報警原因不明確,或處理后仍未消除,歡迎隨時聯系您的GENMA售服工程師,我們可以協助您進一步排查。定期按周期更換機油、濾清器,保持燃油系統清潔,很多報警可以提前避免。
GENMA Maintenance · Emergency & Troubleshooting | Generator Set Alarm Checks
On GENMA machines equipped with a diesel generator set, the generator is an important power source. If something isn't right, the touchscreen will show an alarm. Understanding it promptly and responding correctly helps prevent a small issue from becoming a major failure.
The diesel generator status page can be accessed from the information page. The touchscreen shows the current operating status and any alarm messages. If the status page displays an alarm error, please check and address it promptly.
Common areas to check
1. Fluid levels and leaks
Check lubricating oil and coolant levels
Check for leaks in fuel, lubricating oil, and coolant
2. Operating parameters
Check oil pressure and coolant temperature
Check for changes in power performance
Listen for abnormal engine noise
Check for abnormal exhaust smoke color
3. Intake and fuel system
Every 50 hours: check the air intake restriction indicator, or replace the air filter element
Every 50 hours: drain water and sediment from the fuel tank
Every 50 hours: drain water and sediment from the fuel filter
4. Belts and fan
Check belts for looseness and wear
Check the fan for damage
If the cause of an alarm isn't clear, or it persists after handling, feel free to contact your GENMA service engineer — we can help you investigate further. Replacing oil and filters on schedule and keeping the fuel system clean can prevent many alarms before they occur.
聲明:本文系轉載自互聯網,請讀者僅作參考,并自行核實相關內容。若對該稿件內容有任何疑問或質疑,請立即與鐵甲網聯系,本網將迅速給您回應并做處理,再次感謝您的閱讀與關注。
不想錯過新鮮資訊?
微信"掃一掃"